Directory

Encyclopedia

NodeWorks
                              ENCYCLOPEDIA

Link Checker

Home
Encyclopedia : G : GL : GLO :

Glossary of wildland fire terms

 

Glossary of wildland fire terms


A

  • Aerial firefighting: Use of aircraft to combat wildfires.
  • Airtanker: Fixed-wing aircraft certified by FAA as being capable of transport and delivery of fire retardant solutions. Coordinates air tankers for fire retardant drops.
  • Anchor point: An advantageous location, usually a barrier to fire spread, from which to start constructing a fireline. The anchor point is used to minimize the chance of being flanked by the fire while the line is being constructed.

    B

  • Backburn: Precautionary fire set downwind of main fire for controlled fuel clearing by "backing" it into the main fire, similar to burnout, below, which occurs adjacent to control line.
  • Backfire: A fire set along the inner edge of a fireline to consume the fuel in the path of a wildfire and/or change the direction or force of the fire’s convection column.
  • Bambi bucket®: collapsible bucket for lifting and moving water or other fire retardant with a helicopter. (Note: The name was in use many years before the trademark owner claimed it in 1983.)
  • Barrier: Any obstruction to the spread of fire. Typically an area or strip devoid of combustible fuel.
  • Base: (1) staging and/or command center location for fire operations; (2) starting location of a fire; (3) base camp: location for eating, sleeping, etc., near staging or command center.
  • Berm: Soil heaped on the downhill side of a traversing fireline below a fire, to trap rolling firebrands.
  • Blowup: Sudden increase in fireline intensity or rate of spread of a fire sufficient to preclude direct control or to upset existing suppression plans. Often accompanied by violent convection and may have other characteristics of a firestorm.
  • Boise Interagency Fire Center (BIFC): The former name of the National Interagency Fire Center (see below); often pronounced as "biff-see".
  • Booster hose, booster pump, booster reel: small solid hose on a reel connected to a small pump fitted to a water tank on a vehicle. Booster pump also refers to pump in a relay series for pumping uphill beyond the lift of the previous pump.
  • Brush blade: Rake attachment for cutting or ripping brush and roots out of a fireline.
  • Brush hook: Cutting tool used to clear brush, longer than a machete, usually with a heavy, solid,curved blade bolted to the end of an arm's-length handle.
  • Brush truck: Small fire truck outfitted for wildland fire. Also called a "Type 6 Engine."
  • Bump up: To move to another location. Can refer to anything from moving to another location on a fireline, to an entire crew moving to another fire. Likely derived from "boom up" (see: boomer). "Bump back" means to return to your previous location. In the "bump" system of fireline construction, each firefighter works on a small piece of fireline with his or her tool, perhaps slowly walking as the line progresses, until a completed portion of line is encountered. Then the call to "bump up!" is heard, and everyone ahead of the caller skips ahead one or more positions, leaving the unfinished fireline for those coming up behind.
  • Burning index: relative measure of fire-control difficulty; doubling the index means twice the effort may be needed to control the fire (e.g., wind shift, heavier fuel load, etc).
  • Burn out: Setting fire inside a control line to consume fuel between the edge of the fire and the control line.
  • Burning period: The part of each 24-hour period when fires spread most rapidly; typically from 10:00 AM to sundown.

    C

  • Closed area: An area in which specified activities or entry are temporarily restricted to reduce risk of human-caused fires.
  • Closure: Legal restriction, but not necessarily elimination, of specified activities such as smoking, camping, or entry that might cause fires in a given area.
  • Cold trailing: A method of controlling a partly dead fire edge by carefully inspecting and feeling with the hand for heat to detect any fire, digging out every live spot, and trenching any live edge.
  • Complex: Two or more individual incidents located in the same general area which are assigned to a single incident commander or unified command.
  • Confine a fire: The least aggressive wildfire suppression strategy which can be expected to keep the fire within established boundaries of constructed firelines under prevailing conditions.
  • Contain a fire: A moderately aggressive wildfire suppression strategy which can be expected to keep the fire within established boundaries of constructed firelines under prevailing conditions.
  • Control line: An inclusive term for all constructed or natural barriers and treated (retardant) fire edges used to control a fire.
  • Controlled burn: See Prescribed Burn.
  • Coyote tactics: A progressive line construction duty involving self-sufficient crews which build fireline until the end of the operational period, remain at or near the point while off duty (in a spike camp), and begin building fireline again the next operational period where they left off.
  • Creeping fire: Fire burning with a low flame and spreading slowly.
  • Crown fire: A fire that advances from top to top of trees or shrubs more or less independent of a surface fire. Crown fires are sometimes classed as running or dependent to distinguish the degree of independence from the surface fire.
  • Crown out: A fire that raises from ground into the tree crowns and advances from treetop to treetop. To intermittently ignite tree crowns as a surface fire advances.

    D

  • Demob: Demobilization, or a crew being removed from working a fire.
  • Direct Attack: Any treatment applied directly to burning fuel such as wetting, smothering, or chemically quenching the fire or by physically separating the burning from unburned fuel.
  • Dozer line: Fireline constructed by the front blade of a bulldozer or any tracked vehicle with a front mounted blade used for exposing mineral soil. Also "catline."
  • Drafting: using a suction pump to lift water from below the pump, using a semi-rigid suction hose, typically to fill a portable reservoir that has other suction pumps (to relay) or siphon hoses running downhill to their nozzles.
  • Drip torch: hand-carried fire-starting device filled with flammable liquid that is poured across a flaming wick, dropping flaming liquid onto the fuels to be burned.

    E

  • Engine: Any ground vehicle providing specified levels of pumping, water, and hose capacity but with less than the specified level of personnel.
  • Engine crew: A number of personnel trained and supervised to respond to incidents using an engine. Typically much smaller than a hand crew.
  • Escaped fire: A fire, which has exceeded or is expected to exceed initial attack capabilities or prescription.
  • Extended attack: Situation in which a fire cannot be controlled by initial attack resources within a reasonable period of time. Committing additional resources within 24 hours after commencing suppression action will usually control the fire.

    F

  • Fire behavior: The manner in which a fire reacts to the influences of fuel, weather, and topography.
  • Fire camp: Temporary camp established at large fires to provide food, rest, and other necessities to fire crews.
  • Firebreak: A natural or constructed barrier used to stop or check fires that may occur, or to provide a control line from which to work.
  • Fire edge: The boundary of a fire at a given moment.
  • Fireline: The part of a control line that is scraped or dug to mineral soil. Also called fire trail. More generally, working a fire is called being "on the fireline."
  • Fireline handbook: A small red booklet carried by U.S. firefighters on the firelines, as a quick reference on various firefighting topics.
  • Fire retardant: Any substance (except plain water) that by chemical or physical actions reduces flammability of fuels or slows their rate of combustion.
  • Fire shelter: An aluminized tent offering protection by means of reflecting radiant heat and providing a volume of breathable air in a fire entrapment situation. Fire shelters should only be used in life threatening situations, as a last resort.
  • Firestorm: Extreme fire behavior indicated by widespread in-drafts and a tall column of smoke and flame, where added air increases fire intensity, creating runaway fire growth.
  • Fire weather: weather conditions that affect fire vulnerability, fire behavior and suppression.
  • Flanks of a fire: The parts of a fire’s spread perimeter that are roughly parallel to the main direction of spread.
  • Flare-up: Any sudden acceleration in rate of spread or intensification of the fire. Unlike blowup, a flare-up is of relatively short duration and does not radically change existing control plans.
  • Flash fuels: Fuels such as grass, leaves, draped pine needles, fern, tree moss and some kinds of slash, which ignite readily and are consumed rapidly when dry.
  • Foam: The aerated solution created by forcing air into, or entraining air in water containing a foam concentrate by means of suitably designed equipment or by cascading it through the air at a high velocity. Foam reduces combustion by cooling, moistening and excluding oxygen.
  • Fuelbreak: A natural or manmade change in fuel characteristics which affects fire behavior so that fires burning into them can be more readily controlled.
  • Fuel load: the mass of combustible materials available for a fire usually expressed as weight of fuel per unit area (e.g., 20 tons per acre).
  • Fuel type: An identifiable association of fuel elements of distinctive species, form, size, arrangement, or other characteristics that will cause a predictable rate of spread or resistance to control under specified weather conditions.

    G

  • Ground fire: Fire that consumes the organic material beneath the surface litter ground, such as peat fire.

    H

  • Hand crew: A number of individuals that have been organized and trained and are supervised principally for operational assignments on an incident. In the United States, a typical hand crew is 20 in number.
  • Head of a fire: The most rapidly spreading portion of a fire’s perimeter, usually to the leeward or up slope.
  • Heavy fuels: Fuels of large diameter such as snags, logs, large limb wood, which ignite and are consumed more slowly than flash fuels.
  • Helispot: A natural or improved takeoff and landing area intended for temporary or occasional helicopter use, typically in remote areas without other access.
  • Helitack: A fire crew trained to use helicopters to move personnel, equipment and supplies to helispots, for direct attack or to stage for coyote tactics.
  • Hot spot: A particularly active part of a fire.
  • Hotshot crew: Intensively trained fire crew used primarily in hand line construction.

    I

  • Incident Command System (ICS): System first developed to provide a command structure to manage large wildfires in the United States, now widely used by many emergency management agencies.
  • Indian pump: Water vessel carried on one's back, either a rigid can or collapsible bag, with a hose and telescoping squirt pump. Contains 5 US gal, and is used on hot spots and during mop up. Also called bladder bag (if collapsible), piss pump, or Fedco.
  • Indirect attack: A method of suppression in which the control line is located some considerable distance away from the fire’s active edge. Generally done in the case of a fast-spreading or high-intensity fire and to utilize natural or constructed firebreaks fuel breaks and favorable breaks in the topography. The intervening fuel is usually backfired; but occasionally the main fire is allowed to burn to the line, depending on conditions.
  • Infrared (IR) detector: A heat detection system used for fire detection, mapping, and hotspot identification.
  • Initial attack: The actions taken by the first resources to arrive at a wildfire to protect lives and property, and prevent further extension of the fire.
  • Interface zone: Where urban firefighting meets wildland firefighting. Structures at the edges of wildlands are threatened and require skills and equipment of both disciplines.

    K

  • Knock down: To reduce the flame or heat on the more vigorously burning parts of a fire edge.

    L

  • Ladder fuels: Flammable vegetation that helps a ground fire move into the canopy.
  • LCES: Firefighter safety mnemonic for Lookouts, Communications, Escape routes, Safe zones.
  • Lead plane: Aircraft with pilot used to make trial runs over the target area to check wind, smoke conditions, topography and to lead air tankers to targets and supervise their drops.
  • Let-burn policy: Administrative decision to defer fire suppression, perhaps because of wilderness and long-term forest conservation considerations.
  • Light 'em, fight 'em: Derogatory term for wildland crew with a reputation for igniting its prescribed burns carelessly.
  • Line firing:
  • Litter: Surface buildup of leaves and twigs.
  • Logging slash or logging debris:
  • Longline: Helicopter arrangment for lowering external loads into areas not available for landing.
  • Lookouts: (1) Safety person positioned to monitor the location and behavior of a fire, ready to sigal a crew to escape; (2) Lookout towers, often on mountain-tops, for viewing the surrounding countryside and watching for signs of fire; (3) The "L" of "LCES" safety mnemonic, which see above.

    M

  • McLeod: Hand tool used in fireline construction, consisting of a combination rake and hoe.
  • Mop-up: Extinguishing or removing burning material near control lines, felling snags, and trenching logs to prevent rolling after an area has burned, to make a fire safe, or to reduce residual smoke.
  • Mutual aid: cross-jurisdictional assistance with emergency services by pre-arranged agreement.

    N

  • National Fire Protection Association (NFPA): Fire and safety standards organization; issues various wildfire-oriented standards related to clothing, tactics, equipment, etc.
  • National Hose (NH): National Standard Thread (NST) design of threaded couplings used on fire hose in various diameters.
  • National Interagency Fire Center (NIFC): Coordination facility in Boise, Idaho, operated by several U.S. agencies to provide logistics, weather information and resource coordination for wildfire suppression across the U.S. (formerly BIFC).
  • Nomex®: Brand of approved, fire retardant, synthetic, aramid cloth and thread used in personal protective equipment for wildland firefighting, and jumpsuits.

    O

  • Overhead: Personnel assigned to supervisory positions, including Incident Commander, Command Staff, General Staff, Branch Directors, Supervisors, Unit Leaders, Managers, and staff.

    P

  • Prescribed burn: Deliberately ignited fire for the purpose of forest or prairie management, often to remove excess fuel buildup or simulate natural cycles of fire in an ecosystem.
  • Project fire: Any large fire requiring extensive management and the establishment of a temporary infrastructure to support firefighting efforts, such as fire camps.
  • Pulaski: Combination axe and grub hoe tool with a straight handle, used for building handline.

    R

  • Rapeller: Crew of specialist hot-shot firefighters who are trained to access a fire area by sliding down ropes suspended from a hovering helicopter. Also used for delivering wilderness first aid if a rapeller is an EMT.
  • Reburn: (1) Repeat burning of an area over which a fire has previously passed, but left fuel that later ignites when burning conditions are more favorable; (2) An area that has re-burned.
  • Red card: Credentials issued to qualified wildland firefighters, listing their qualifications and specialties.
  • Red-flag day: Weather conditions creating a critical fire hazard, may require closing the forest to non-emergency activities in order to minimize the risk of accidental wildland fires.

    S

  • Safety zone: An area cleared of flammable material used for escape in the event the line is outflanked or in case a spot fire causes fuels outside the control line to render the line unsafe. In firing operations, crews progress so as to maintain a safety zone close at hand allowing the fuels inside the control line to be consumed before going ahead. Safety zones may also be constructed as integral parts of fuel breaks; they are greatly enlarged areas which can be used with relative safety by firefighters and their equipment in the event of blowup in the vicinity.
  • Sawyer: Chain-saw crew, may also include ‘’’faller’’’ or ‘’’feller’’’ who is qualified to cut down trees or snags, perhaps while the tree or snag is burning.
  • Secondary line: Any fireline constructed at a distance from the fire perimeter concurrently with or after a line already constructed on or near to the perimeter of the fire. Generally constructed as an insurance measure in case the fire escapes control by the primary line.
  • Skidder unit: Pre-configured tank, pump, hose for attachment to a logging skidder (large 4-wheel-drive tractor with a dozer blade, winch or grapple) to be carried to a fireline.
  • Slash: Debris resulting from such natural events as wind, fire, or snow breakage; or such human activities as road construction, logging, pruning, thinning, or brush cutting. It includes logs, chunks, bark, branches, stumps, and broken under-story trees or brush.
  • Slopover: Fire spreading outside the boundaries of a control line.
  • Slurry bomber: See Airtanker.
  • Smokechaser: Colloquial term for a wildland firefighter. Now mostly archaic, except in Minnesota where state Department of Natural Resources firefighters are officially known by that name.
  • Smokejumper: A specifically trained and certified firefighter who travels to wildland fires by aircraft and parachutes to a landing zone near the fire.
  • Smoldering: A fire burning without flame and barely spreading.
  • Spike camp: Remote camp usually near a fireline, and lacking the logistical support that a larger fire camp would have.
  • Spotting: Behavior of a fire producing sparks or embers that are carried by the wind and which start new fires (spot fires) beyond the zone of direct ignition by the main fire. A cascade of spot fires can cause a blowup.
  • Strike team: Specified combinations of the same kind and type of resources, with communications, and a leader.
  • Suppression: All the work of extinguishing or confining a fire beginning with its discovery.
  • Suppression crew: Two or more firefighters stationed at a strategic location for initial action on fires. Duties are essentially the same as those of individual firefighters.
  • Surface fire: Fire that burns loose debris on the surface, which include dead branches, leaves, and low vegetation.

    T

  • Task force: Any combination or single resources assembled for a particular tactical need, with common communications and a leader. A Task Force may be pre-established and sent to an incident, or formed at an incident.

    U

  • Understory burn: A controlled burn of fuels below the forest canopy, intended to remove fuels from on-coming or potential fires.
  • Urban interface: The Interface zone where man-made structures inter-mingle with wildlands, creating risk of structural involvement in a wildland fire incident.

    W

  • Watch out situations: A list of 18 situations for firefighters to be aware of, which signal potential hazards on the fire line.
  • Water tender: Any ground vehicle capable of transporting specified quantities of water.
  • Wet line: Temporary control line using water or other fire retardant liquid to prevent a low-intensity fire from spreading in surface fuels.
  • Wildfire: A fire occurring on wildland that is not meeting management objectives and thus requires a suppression response.
  • Wildland: An area in which development is essentially nonexistent, except for roads, railroads, power lines, and similar transportation facilities. Structures, if any, are widely scattered.
  • Windfall: Tree knocked over or broken off by wind, increases fuel loading and hampers building fireline. Also sometimes called blowdown.

    See also

    Glossary of firefighting terms

    External refs

    U.S. govt source file


  • NodeWorks boosts web surfing!
    Page Returned in 0.239 seconds - HTML Compressed 63.1%

    This article is from Wikipedia. All text is available
    under the terms of the GNU Free Documentation License.
     GNU Free Documentation License
    © 2008 Chamas Enterprises Inc.